Filter Results By:
Products
Applications
Manufacturers
Rubidium Reference
In telecommunication, a rubidium standard is a frequency standard in which a specified hyperfine transition of electrons in rubidium-87 atoms is used to control the output frequency. (www.encyclopedia.thefreedictionary.com)
See Also: Rubidium Standards
-
product
4210A Rubidium Frequency Standard
Precise Time and Frequency, Inc.
The ptf 4210A Rubidium Frequency Standard is a unique solution for providing a highly stable, low phase noise, frequency reference for applications requiring atomic reference stability performance.The instrument contains a high performance rubidium module, with an extended life design, and very low aging rate, with high quality OCXO o/p for low phase noise.
-
product
Frequency Reference
Quartzlock time and frequency standards offer a complete range of cost effective and low noise in both atomic controlled (rubidium oscillator) and GPS controlled (off-air) time and frequency reference, calibrators and standards. These acurate time and frequency references are used in telecoms, aviation, nautical and precision test and measurement enviroments.
-
product
Rubidium Oscillators
Our range of precise low noise rubidium oscillators in a variety of sizes to suit all appliations. These acurate frequency references are used in telecoms, aviation, nautical and precision test and measurement enviroments.
-
product
GPS Time and Frequency Standards
Our range of GPS disciplined Rubidium Oscillator, OCXO and TCXO, low cost and stable, time and frequency references in a variety of rack mount and desktop sizes to suit all applications. For a technical discussion of GPS go here or select a link below for product information.
-
product
8-Channel, 10 MHz Precision ReferenceWith Sine and Logic Outputs
ITS-6200
The ITS-6200 is a versatile 10 MHz laboratory frequency reference useful for synchronizing test instruments to a common standard. Eight outputs are provided, each which can be configured independently as sinewave or logic level square-wave signals. Additionally, CMOS logic levels can be set for 5V, 3.3V, or 2.5V logic family compatibility. A 10 MHz reference input is provided to phase lock the ITS-6200 to an external reference, such as a GPS or Rubidium standard, or cascade multiple ITS-6200 units for additional outputs. The low phase noise and high stability OCXO within the ITS-6200 is suitable for the most demanding applications, whether free-running or phase locked. The compact size and low power consumption makes the instrument highly portable and suitable for AC-powered operation in the lab or battery operation in mobile or field applications.
-
product
Rubidium Reference Oscillator
VCH-210
The rubidium reference generator VCH-210 is designed to generate a highly stable reference and clock signal.
-
product
Reference Frequency Generator
MFCh
*Frequency reproduction accuracy ± 2 x 10 -9 *Output frequency 1 Hz - 10 MHz *Output pulse signal 1 kHz The MFC is designed to generate high-frequency pulse signals with a frequency of 1 kHz and a frequency in the range from 1 Hz to 10 MHz along two output lines. The MFC is designed to operate in measuring systems based on the VXIbus trunk. In the MFC, a rubidium frequency standard is used as a reference frequency source. Time to reach the mode when the power source of the rubidium standard is turned on, no more than 10 min
-
product
Rubidium Frequency Standard
RFS VXI
*RFS VXI is designed to work as part of information measuring systems based on the VXI bus as a rubidium frequency standard.*RFS VXI is intended for use as a highly stable laboratory signal source for checking generator devices, time-frequency measuring equipment and other equipment, synchronizing navigation systems.*The RFS VXI contains two independent rubidium reference oscillators: main and standby.*RFS VXI is a VXI standard, register based device and measures C-1.*RFS VXI implements the "Self-control" mode, which checks the output frequencies of the rubidium standard.
-
product
Ultra Low Noise, Rubidium Frequency Standard.
A10-M
Frequency Referencing, Calibration, Standards Lab, Production Test for Oscillator Manufacturers. A very high stability LOW NOISE 10MHz Rubidium Reference, primarily for production test of quartz oscillators and RF instrumentation frequency referencing. This industry standard 2U rack-mount instrument has a long heritage and ongoing production life for this latest 2009 version that features RS232 monitoring and control of the DPLL, locking the Ultra Low Noise OCXO to the Rubidium. Damping and Bandwidth is controlled by integrator digital gain, proportional digital gain, pre-filter order and subsample rate. Eight values of user selected bandwidth are available.
-
product
Rubidium Oscillators
Our range of atomic / rubidium disciplined time and frequency standards in a variety of enclosures and sizes to suit all appliations. These acurate time and frequency references are used in telecoms, aviation, nautical and precision test and measurement enviroments.
-
product
Rubidium Instruments
Our range of atomic / rubidium disciplined time and frequency standards in a variety of enclosures and sizes to suit all appliations. These acurate time and frequency references are used in telecoms, aviation, nautical and precision test and measurement enviroments.
-
product
Space Qualified Oscillators
Our range of space qualified precise low noise rubidium oscillators. These highly accurate space qualified frequency references are used in Satellite Navigation Systems, Intelligence Reconnaissance Satellites, Military Communication Satellites, Deep-Space Survey and Space Stations
-
product
Rubidium Reference Oscillator
LPFRS-01
Rubidium reference generator LPFRS-01 is designed to generate a highly stable reference and clock frequency signal.
-
product
Compact Timing Systems
NanoSync IV & NanoSync IV Low Profile
The NanoSync IV is a small form factor GPS Position, Navigation, Time (PNT) and Frequency reference system that provides multiple reference outputs and includes support for NTP & PTPv2 IEEE 1588-2008. The NanoSync IV has a Rubidium oscillator and is available with a civilian C/A GPS receiver or SAASM (Rockwell-Collins MPE-S GB-GRAM or Trimble Force 22E MRU GPS receiver) for military users. The NanoSync IV is packaged in a small, rugged enclosure ideally suited for embedded electronic warfare applications.The NanoSync IV-SA-Rb has been demonstrated to be compliant to the Joint Airborne SIGINT Architecture (JASA) Version 3.0, Annex 1, for Time, Frequency, Navigation and Geodesy (TFNG), making it suitable for Electronic Warfare (EW) COMINT and ELINT applications in fixed site, airborne and shipboard environments.
-
product
Frequency Standards
Precision Test manufacturers a complete range of frequency standards. This includes rubidium and OXCO models either free running or controlled by an external reference (GPS, GLONASS, Galileo, 1pps, 5 MHz, 10 MHz, IRIG-B etc). Output frequencies typically 1 MHz, 5 MHz, 10 MHz, 10.23 MHz, 13 MHz, 100 MHz or bespoke frequency.
-
product
GPS/GLONASS Disciplined Rb Oscillator
VCH-311
GPS/GLONASS disciplined rubidium frequency standard model VCH-311 is a high stable frequency signal source (STANDARD mode), or precision frequency calibrator for any external standard signals (CALIBRATOR mode). The instrument contains multi-channel GPS/GLONASS receiver, time scale comparison unit and automatically adjustable Rubidium reference oscillator.
-
product
Rack-Mounted Timing Systems
CommSync II Family
The CommSync II family of modular systems provide GPS time and frequency outputs to meet your synchronization requirements. All systems include support for multiple input and output modules including 1PPS, IRIG, HAVE QUICK, PTTI, IEEE-1588 PTPv2, low phase noise 1, 5, and 10 MHz sine wave as well as custom outputs.These systems are available with military SAASM MPE-S GB-GRAM, SAASM Force 22E MRU or civilian C/A GPS receivers. Rubidium or OCXO oscillators provide for excellent holdover performance in the event of failure of the reference inputs. In addition, they may be configured as Distribution Time and Frequency (DTF) systems that are synchronized by an external reference. Dual Redundant systems (CommSync II & CommSync II-D) may be configured with two GPS Time & Frequency (GTF) modules and two power supply modules (AC and/or DC power) for redundancy with uninterrupted automatic switchover.
-
product
Rubidium Oscillator
Rubidium oscillators are a type of atomic clock and are the most accurate time standards known and are used as time distribution services to control things such as telecommunications infrastructure, TV broadcasts and global navigation satellite systems (GPS).
-
product
Rubidium Frequency Standards
Incorporating time-tested and field-proven technology, these rubidiums deliver high-precision time and frequency accuracy for measurement equipment. Products are available in VXI and PXI versions.
-
product
Rubidium Oscillator
IQRB-2
The IQRB-2 low noise rubidium oscillator is a sub-miniature atomic oscillator combined with 'active noise filter' technology. This rubidium oscillator has 100 times less drift than OCXOs and with short term stability of 0.002ppb/s at 100s this rubidium oscillator provides significant improvements in performance over other rubidium components.
-
product
Reference Supplies
Advanced Energy's Trek reference supplies offer both high temperature and time stability outputs. They can also be used as a secondary traceable standard.
-
product
Reference Sources
A physical or digital document that you would refer to for more information about a topic.
-
product
Reference Standard
Beijing GFUVE Electronics Co.,Ltd.
It has been designed for universal laboratory and test applications and is intended for checking and the calibration of reference standards for electrical power and energy.
-
product
Reference Cells
Reference cell is used for measuring and setting the intensity of solar simulators for one sun (or other user desired) intensity condition. They are also used to calibrate the IV Measurement system photo-detector intensity to match the measured ISC to calibrated ISC.
-
product
Reference Magnets
Reference Magnets provide a stable and convenient method to verify the accuracy and calibration of Hall Effect Gaussmeters, Teslameters, and Probes.
-
product
Reference Antennas
Type NRD
Reference antennas are precision dipole antennas that offer a fixed 2.15 dB of gain over an isotropic antenna along the major lobe axis at specified frequencies (2.15 dBi). They are intended to be used for antenna field pattern and gain measurements, or general RF sensing in the laboratory.
-
product
Voltage References
Maxim offers an industry-leading portfolio of shunt and series voltage reference ICs. We were the first to develop a series reference in a 3-pin SC70 and in chip-scale packaging. Our hundreds of voltage references include high-accuracy, low-power, low-noise, and automotive-grade products.
-
product
Micropower Voltage Reference
ISL21010
The ISL21010 is a precision, low dropout micropower bandgap voltage reference in a space-saving SOT-23 package. It operates from a single 2.2V to 5.5V supply (minimum voltage is dependent on voltage option) and provides a ±0.2% accurate reference. The ISL21010 provides up to 25mA output current sourcing with low 150mV dropout voltage.
-
product
RF Reference Sources
The 27 GHz 96270A and 4 GHz 96040A Low Phase Noise Reference Sources are designed specifically for RF calibration, featuring a calibration-oriented interface, precision signal level and attenuation, high signal purity and precision low distortion modulation. Both instruments simplify the process of RF calibration by reducing the amount of equipment and simplifying the calculations required.
-
product
Reference Meters
Whether standard or high precision, ThermoWorks handheld meters feature rugged housing and best-in class accuracy across a variety of temperature ranges. Choose from integrated systems or meters that accept multiple probes, single or dual channel meters, alarms or reference models. Perfect for BBQ or sous-vide applications, dairy processing and meat processing, pharmaceutical labs, concrete curing, health departments, and for line checks, critical control point management, and HACCP checklists.