Filter Results By:
Products
Applications
Manufacturers
Current Shunts
Resistors with known accurate values to measure current.
See Also: Shunts, AC Current Shunts
- Pickering Interfaces Inc.
product
PXI/PXIe Wide Current Range Multiplexer Module, Quad 3-Channel, 2-Pole
42-514-103
The 40-514-103 (PXI) and 42-514-103 (PXIe) are low density multiplexers in quad 3-channel, 2-pole configuration. They are capable of switching a wide range of current, from 10 μA to 2.5 A at 220 VDC/250 VAC. The current capability of the module permits the use of a single module type for both low and medium current test applications.
-
product
Phase Meter Current Shunts
610 and 650
Clarke-Hess Communications Research
The Model 610 and 650 Current Shunts are specifically designed to operate with the Model 6000A Precision Phase Meter. These shunts are frequency tuned to have negligible phase shift (less than 5m) at 50/60Hz making them ideal for line frequency applications. They can also be idealized for other frequencies as specified by the user. Consult factory for details.
-
product
Current Sensing Resistors: ACQ-200
TCS
These components are four-terminal. bus-bar, metal strip current shunts. Assembled using electron beam welding. These units can handle 15W of continuous power and a maximum current of 350A 90.1mohm). Also they can absorb a high pulse power rating and have very low inductance. They also feature excellent long term stability, less than 100ppm/C TCR, and have excellent frequency characteristics.
-
product
Precision Shunts
Ohm-Labs manufactures metrology grade shunts for precise measurement of current from <1 mA to 3000 A.
-
product
Ungrouped
Weshine Electric Manufacturing Co., Ltd
The instrument can measure single capacitor of single phase or three-phase shunt capacitor bank without removing wires.2. The instrument has the functions of inductance, resistance and current measurement.3. The instrument has two power supply modes: External AC220 V and built-in lithium battery meet various application scenarios.
-
product
Impulse Current Measuring Shunts
ICMS
The Impulse Current Measuring Shunts ICMS are new designed tubular shunt types with best response behavior to match the high performance of the TR-AS digital recorder for comparative current measurements. A 1st partial response time less than 10ns and a settling times less than 20ns show the advantage of these shunts. They show no initial overshoot peak, no oscillations and do not need compensation box to optimize the transient behavior as known from e.g. cage shunts.
-
product
ABex Current Sense Module for Six Channel UUT Supply Monitoring
ABex TM-406 Current Sense
The ABex TM-406 is a six-channel shunt current measurement extension. It’s designed to work in combination with the Konrad ABex TM-501 and PXI-501.Each of the six shunt current measurement units have a passive measurement shunt, an overcurrent protection, a sense bridge relay and the possibility to route the quiescence current to an ABex measurement device TM-501 with PXI-501.In addition, the ABex TM-406 features 8 isolated digital outputs (IDOs), and 12 measurement inputs, which can be routed to the analog bus.
-
product
Data Acquisition Recorders & Loggers
DAS1800
The DAS1800 can be configured for a wide variety of applications with slots for 10 input modules each supporting 4 or 8 measurement channels. Acquire data from any sensor with a voltage or current output (with shunt), or directly measure voltage, resistance, or temperature using thermocouples or resistance temperature detectors (RTDs).
-
product
Shunt Isolation Amplifier
Knick Elektronische Messgeräte GmbH & Co. KG.
Especially to accurately measure large DC currents via shunt resistors, ie for making isolated detection of mV voltage on shunts. Variants with calibrated range selection. Working voltage up to 3600 V AC / DC.
-
product
Transconductance Amplifier
1620A
The 1620A provides high accuracy current levels from dc to over 10 kHz for calibrating ammeters, current transformers and shunts. It also provides output current up to 100 Amperes and as such may also be used as a high accuracy power supply, and as a power source in welding and bonding applications.
-
product
AC Power Analyzers
Measure voltage, current and power on 4 channels: DC, 1-phase AC or 3-phase ACMake more accurate power measurements: 0.05% at 50/60 HzMeasure current directly: internal shunts to 50 Arms, or with external probes or transducersAddress multiple test scenarios with isolated inputs
-
product
Dual Wide Range Power Monitor
LTC2992
The LTC®2992 is a rail-to-rail system monitor that measures current, voltage, and power of two supplies. It features an operating range of 2.7V to 100V and includes a shunt regulator for supplies above 100V. The voltage measurement range of 0V to 100V is independent of the input supply. Two ADCs simultaneously measure each supply’s current. A third ADC monitors the input voltages and four auxiliary external voltages. Each supply’s current and power is added for total system consumption. Minimum and maximum values are stored and an overrange alert with programmable thresholds minimizes the need for software polling. Data is reported via a standard I2C interface. Shutdown mode reduces current consumption to 25μA typically.
-
product
L Terminal Shunt Resistor
LT
LT shunts are highly accurate manganin resistance D.C. shunts. These shunts are designed for standard current measurement of electric equipment.
-
product
Cross Voltage Testers
designed to perform the 60 Hz power line cross test/AC power fault tests required in GR 1089 issue 6 table 4.5 surge test 3,4, 4.3,and 6, and for UL 1950 section 6.4 paragraph 3 and 4.. Preset and Adjustable Time Settings Measuring Terminals including Voltage Sense and Current Shunt portals provide a safe location for users to accurately measure test voltages and output current while setting up tests. Calibration of the Mini_PT-600 is designed to be performed with a simple handheld multi-meter and the removable Currents Shunts can be easily sent to a calibration laboratory if required.
-
product
SparkFun Current Sensor Breakout
INA169
The INA169 is a “high-side current monitor,” which means that you place a resistor (a “shunt resistor”) on the positive power rail and the INA169 measures the voltage drop across that resistor. The INA169 outputs a small current based on the measured voltage drop. If you place a resistor from the output of the INA169 to ground, you can measure the voltage at the output.
-
product
Precision Current Shunt
Has five precision selectable Ultra stable Current Shunts which ranges from 0.0001 to 1Ω. The Shunt T/C is less than 10ppm, and the internal current meter will measure from 1μA to 1000Amps.
-
product
Wide Angle Scale Instrument
LS-96
Standard Electric Works Co., Ltd
● For ranges higher than 20A DC, use external shunt with a 50mV DC Ammeter.● For ranges higher than 300V DC, use external Volt Divider with a 1mA Voltmeter.● For ranges higher than 5A AC, use external Current Transformer with a 5A AC Ammeter. ● For ranges higher than 600V AC, use external Potential Transformer with a 150V AC Voltmeter.● Full Scale Deflection : 250° ● Accuracy : Class 1.5● Composition : Glass window, ABS resin frame and case, PC glass fiber base mounting fittings included.● Color : Black base and frame, white scale plate and meter body.● Pointer : Stick shape in black color.
-
product
Micropower Voltage References
Analog Devices offers a broad line precision micropower voltage references with extremely low quiescent currents (series references) or minimum shunt currents (shunt voltage references). All of our precision voltage references offer excellent initial accuracy and low temperature drift over time and temperature. Our Reference Plus products combine precision voltage references with comparators or amplifiers.
-
product
Differential Sensor, Wide Dynamic Range, 100 MHz
CX1105A
The CX1105A ultra-low noise differential sensor is a dedicated accessory for the CX3300 series and enables dynamic current measurements from 1 μA to 100 A under up to 100 MHz bandwidth with existing shunt resistors on your test board.
-
product
Multi-Channel Digital Power Meters
66203/66204
Chroma Systems Solutions, Inc.
Voltage Range :15/30/60/150/300/600 VrmsCurrent Range :0.005/0.02/0.05/0.2/0.5/2/5/20 ArmsFrequency Range : DC, 15Hz~10kHzEmbedded high speed DSP, 16 bits Analog/Digital convertersHalf rack size, 4 input modules design (66204)Support different wiring configuration power measurement (1P2W/1P3W/3P3W/3P4W)Support external shunt and CT for higher current measurement application5 mA minimum current range & 0.1mW power resolutionMeets ENERGY STAR / IEC 62301 /ErP measurement requirementsAccumulated energy methods for unstable power measurementUser-define criteria provides automatic PASS/FAIL indicationsDual current shunt design provides high accuracy over a wide current rangeTHD and user-specify order distortion measurementInrush current and energy measurementVoltage/ Current harmonics measurement up to 50 orders
-
product
DC Power Analyzer, Modular, 600 W, 4 Slots
N6705C
The N6705C DC Power Analyzer provides unrivaled productivity gains for sourcing and measuring DC voltage and current into the DUT by integrating up to 4 advanced power supplies with DMM, Scope, Arb, and Data Logger features. The N6705C eliminates the need to gather multiple pieces of equipment and create complex test setups including transducers (such as current probes and shunts) to measure current into your DUT. The DC Power Analyzer also eliminates the need to develop and debug programs to control a collection of instruments and take useful measurements because all functions and measurements are available at the front panel. For even greater control and analysis functions, the DC Power Analyzer can be used with the 14585A Control and Analysis Software. When automated bench setups are required, the N6705C is fully programmable over GPIB, USB, LAN and is LXI Compliant. 14585A Control and Analysis Software
-
product
Precision AC/DC Active Current Shunt
2575A
A versatile, powerful calibration tool, the 2575A Precision AC-DC Active Current Shunt measures both AC/DC current and works as a standard for low-level resistance calibration requirements.
-
product
High Current Calibrator
MC151
MC151 Current calibrator is an accurate current source capable of 120 A. Typical uses include calibration of current sensors, current probes, current transformers, shunts, ammeters, DMMs or as stable current source for test and development applications. The calibrator is equipped with a built-in multimeter that can be used for simulation of programmable transconductance or current amplifier.
-
product
Shunts
WSM alternating current measuring resistors have compared with traditional direct current shunt resistors with coaxial voltage tap significantly better high-frequency transmission characteristics. This resulted from a production engineering very complicated structural design of the active part.ISM pulse current measuring resistors allow the metrological recording of the time curve fast current changes large amplitude in the nanosecond range. The ISM are designed for the pulse current measurement with broadband oscilloscopes.
-
product
Shunts
Highly accurate manganin resistance d.c shunts. When a current is passed through the shunt a proportional millivolt output is produced.
-
product
AC Current Shunts
CSA Series
Ohm-Labs’ CSA series of ac current shunts are designed as laboratory standards for ac current measurement up to high frequencies.
-
product
Differential Voltage Probes
DP150/DP200pro
The DP differential isolation probes are an important accessory for any laboratory involved in power electronics and high voltage systems. These probes allow isolated and floating measurements with any oscilloscope or data recorder, whilst the oscilloscope can remain grounded. Using a DP150 or DP200pro probe, differential and floating measurements can be made on a variety of ac power systems like 230V/110V ac input power supplies, chopped and switching power supplies, thyristor controllers, variable speed motor drives (PWM signals), motor inrush current and measurement across current shunts. The isolated input is made via two 4mm/banana safety sockets. The BNC output allows easy connection to an oscilloscope. The DP probes can be powered from a 9V battery or external power supply.
-
product
30 A Current Shunt
34330A
Measure current safely with this precision 0.001 ohm resistor housed in a plastic case surrounded by epoxy.
-
product
Load Cell Amplifier Signal Conditioner with DB9 Connectors
MODEL LCA-9PC
The LCA-9PC Module provides low-cost, dedicated signal conditioning for a single bridge type load cell or torque sensor. Model LCA-9PC comes with DB9 male and female connectors, which require soldering to user-furnished mating female or male wire connectors. On- board jumper selections include sensitivities from 0.5 mV/V to 10 mV/V, bandwidths from 100 Hz to 30 kHz, and amplified outputs of 0 to ±5V, 0 to ±10V, 0-16 mA, 0-20 mA or 4-20 mA. Zero and span adjustments are via precision 25-turn low-tempco metal film otentiometers.The units can be operated next to the sensor with 4-wire hookup or at distances up to 1 km (3300 feet) with 6-wire hookup. An onboard 87.325 kΩ resistor allows easy shunt calibration at the push of a button. Provision is also made for a user-furnished calibration resistor. Power requirements are 11.8 to 26V DC with load currents from 10 to 60 mA, the latter applying when the unit provides 10V DC excitation to a 350 ohm load cell and delivers a 20 mA analog output.
-
product
Shunt Resistor
RSR
Power converters and current measurement instruments. Large current shunt resistor for ampere-meters, designed for standard current measurement of electric equipment. Easy current measurement is performed by attaching to current bus bar directly and connecting to ampere-meter through flexible wires.
-
product
Precision AC/DC Current Shunt
1625A
The BLI 1625A is a multiranging, high accuracy, active current shunt, for use in making NIST traceable measurements of currents from 10 microamperes to 100 Amperes. Very high measurement stability has been achieved in our shunt design by using special alloys, compensated by a proprietary Ballantine process to minimize temperature coefficient effects.