measures the breakdown voltage of insulating oils.
-
product
Fully Automatic Transformer Oil Test Set
1. Test as per International standards NMC insulating oil testers are fully automatic micro controller based system,completely self-contained,compact and portable giving smooth variable test voltage from 0 to 60, 80, or 100 kV for testing the dielectric strength of insulating oil in accordance with all international standards like IEC156/IS6792/ASTM D 1816/ASTM D877/ UNE 21 specifications.2. Auto mode NMC insulating oil testers are fully automatic type.1) IEC-156, IS6792, ASTM D 877, ASTM D 1816, UNE 21.2) Withstand Test A3) Withstand Test B4) 5 Minute Test5) User defined3. 100 Test results storage capacity NMC insulating oil testers has a storage capacity of 100 test results which can be recalled and printed.4. LCD display NMC insulating oil testers use LCD for easy readability of the BDV test results.5. Built in printer The printer used is a thermal paper print outs.The paper rolls can be easily installed by any person.6. User Friendly RS 232 Interface RS 232 interface is very easy to use to communicate stored data which can be saved in text format.7. Safety protection Safety interlocks are provided on the test chamber.Zero interlock protection to ensure operator safety.8. Accurate Performance The kit not only has all basic functions of an insulating oil tester but also has unique features that are seldom seen in similar products. For e.g. PROOF test A, PROOF test B, 5 Minntes test, LCD to display all test data.It ensures high work efficiency and reliability in any tough environment.
-
product
Software
Delta-X
Delta-X provides software diagnostic solutions to assess and track the condition of electrical apparatus used by utilities and heavy industry. Delta-X’s Transformer Oil Analyst™ (TOA) is the market leading tool used by high-voltage equipment experts to manage and interpret insulating fluid test data, including dissolved gas analysis. Generation, transmission and distribution utilities, as well as leading industrial operations around the world, rely on Delta-X to provide accurate and timely insights into the condition of their high-value assets.
-
product
AC Hipot Tester /DC Hipot Tester
YD-Series
Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd
YD series HIPOT tester is applied to test the insulation ability of electric power equipments and insulation materials at power frequency high voltage. The insulation test result of the tester is go or not go. Also the YD series HIPOT tester is a universal power source in HV test. The maximum output voltage and capacity could be customized according the requirements of custom.The tester is consists of single HV transformer and main control box. There are two kinds of HV transformer according to the insulation materials of the HV transformer.They are dry HV transformer and oil HV transformer. For the dry HV transformer the insulation material is epoxy resin.For oil HV transformer the insulation material is insulation oil. The dry HV transformer has a smaller size and less weight than oil HV transformer. But the maximum output voltage is less than 100kv for dry HV transformer. The functions of the main control box are voltage output regulation, protection in emergency and voltage/current value indication
-
product
Electric Insulating Oil Tester
PortaTest
Portatesters are easy to use. Based on the test standard, you select the corresponding test sequence. Then, the required test probe and the electrode gap for the selected test standard is displayed. The setting gauge, included in the scope of delivery, facilitates the adjustment of the electrode gap. Afterwards you fill the insulating oil in the test vessel and close the test chamber.
-
product
Gas Chromatograph for Analyzing
GC2010D
Chongqing Kailian Yongrun Industrial Co.,Ltd.
Transformer uses oil as coolant and insulator. Gases are formed within the transformer oil due to natural aging, faults from oxidation, vaporization, oil breakdown, electrolytic action or insulation decomposition. Because the transformer oil bathes each internal component, dissolved gases in the transformer oil contain lots of diagnostic information. Meanwhile, the transformer is very expensive to be replaced, so monitoring these gases is very important to know the current quality of transformer or even when the transformer should be removed from service before failure. Presence of each gas composition and its concentration indicates possible failure of transformer.
-
product
High-Voltage DC Power Supplies
Higher-voltage and Higher-power Supplies require more complex design solutions. The heat to be dissipated and installation infrastructure, plus choice of insulation system in a HVPS are driven by the output voltage and output power which ultimately dictates packaging. Typical insulation systems are based on air, dielectric oil, epoxy, RTV Silicone and even Sulfur Hexafluoride (SF6). The method of cooling is a factor as well, the choices often coming down to air, water or oil, depending on the platform design requirements. These applications require Excelitas' detailed understanding to help choose the best design solution.
-
product
Transformer Insulation Testing
The primary test methods used to assess the condition of the active insulation components in transformers and bushings, on site, include:1) power factor/tan δ,2) variable frequency power factor/tan δ (1 - 500 Hz)3) dielectric frequency response (DFR) [a dielectric response method], and4) moisture in oil measurements (for transformers).
-
product
*High Current Switches
B-1002
Ross High Current Switches are available up to 36,000 amps continuous and over 1,700,000 amps 20µsec RC pulse, with voltage ratings of 6 volts to 400kV peak test. Standard Ross high current switches are built with 80 to 120psi air cylinder actuators. Air cylinder or motor operated for high contact force. Arcing contacts optional for closing current. G-10 epoxy glass laminate is standard insulation on most models. G-7 silicone glass is used on models available for RF applications above 100kHz. Most Ross high current switches are available with additional lengths of insulation, where the high voltage contacts need to be spaced at a greater distance from the actuator and control circuit. Voltage withstand value is at least doubled and the interrupt capability is much greater when high current switches are immersed in insulating oil, fluid or SF6 gas. For gas atmosphere, no modifications are necessary; however, oil or fluid immersion requires modification at a slight extra cost.
-
product
Oil Tan Delta Tester
OTD
The Oil Tan Delta (OTD) is a laboratory instrument, which measures the Tan Delta, Resistivity and Relative Permittivity of insulating liquids. These tests give a wider picture of the overall quality of the insulating oil, and will indicate if there is any contamination. Megger has developed features of the OTD to ensure that productivity levels within laboratories are maximised. The microprocessor controlled inductive heater means that there is uniformity of temperature throughout the cell, in compliance with IEC 60247, and for cooling a fan effectively speeds up the cell cooling time. The instrument has a temperature measuring range of 10 to 110 C, with an accuracy of 1 C. It can be set to preheat before testing takes place. The automated oil drain facility negates the need to move the oil vessel. User safety is paramount and with this in mind, Megger have designed independent and dual redundant high voltage cut-off circuitry. If for any reason the user needs to abort the test, this can be done so by pressing any key, immediately terminating the test and removing the high voltage. The design of the cell components maximise oil fill rate but minimise turbulence in oil flow and eliminate trapping of air. With only 32 cell components, it is easy to assemble and disassemble.
-
product
Insulation Oil BDV Tester
Wuhan Fanke Transformer Manufacture Co., LTD
Insulation Oil BDV Tester
-
product
Manually Operated Transformer Oil Test Set
We offer Manually operated Transformer Oil Testing Kits to check the DI-electric strength of the insulating Oils as per relevant specifications via. IS 6972. It is a useful equipment for transformer / switchgear manufacturing units. Oil frittering agencies, repair shop and electrical maintenance departments.
-
product
HV Rotary Switches
B-1003
A key feature of our rotary switches is their simple mechanical design which results in conservative stress levels for trouble-free, long life use. In addition, each rotary switch has a reinforced chassis design utilizing G-10 or G-11 fire retardant anti-tracking coated epoxy glass insulation. G-7 silicone glass is used for special applications where RF or high temperatures are involved. Heavy duty contacts, specifically designed to minimize corona in the Ross rotaries, are made of highly conductive yet weld resistant alloy with high contact closing force. This high force gives our rotary switches high momentary current capability and a reputation for their ability to withstand high shock and vibration as well as other severe environmental conditions. Ratings to 150kV, to 200A. When immersed in insulating oil, fluid or gas, the voltage withstand value is at least doubled and the interrupt capability is much greater. In a gas atmosphere, no modification is required. However, immersion in oil or fluid may require modification in some cases, at an extra cost (optional). Each unit is either manually or electrically operated. One SPDT contact is standard on most units. The auxiliary contact is used as an interlock for protection against "Switching Hot".
-
product
Transformer Oil Furan Analyzer
LC2010F
Chongqing Kailian Yongrun Industrial Co.,Ltd.
It is designed to analyze furaldehyde and related furan compounds in transformer oil and other mineral insulating oils.
-
product
High Current Switches
B-1002
Ross High Current Switches are available up to 36,000 amps continuous and over 1,700,000 amps 20µsec RC pulse, with voltage ratings of 6 volts to 400kV peak test. Standard Ross high current switches are built with 80 to 120psi air cylinder actuators. Air cylinder or motor operated for high contact force. Arcing contacts optional for closing current. G-10 epoxy glass laminate is standard insulation on most models. G-7 silicone glass is used on models available for RF applications above 100kHz. Most Ross high current switches are available with additional lengths of insulation, where the high voltage contacts need to be spaced at a greater distance from the actuator and control circuit. Voltage withstand value is at least doubled and the interrupt capability is much greater when high current switches are immersed in insulating oil, fluid or SF6 gas. For gas atmosphere, no modifications are necessary; however, oil or fluid immersion requires modification at a slight extra cost.
-
product
Insulating Oil Testing
BAUR Prüf- und Messtechnik GmbH
Insulating materials are the elixir of life of electrical equipment. These materials lose their insulating and cooling properties due to impuri ties and ageing. This damages equipment, causes failures and is consequently often accompanied by high costs. Precise and reliable measurement results.
-
product
Dry Type Transformer Test
Wuhan Sangao Electrical Test Installations Limit Co.
GTB series dry testing transformer is adopted with new technology of winding epoxy vacuum pouring and CD type Iron core. Compared with similar product of oil immersed type transformer, it is light weight, smaller size, insulation strength and moisture-resistant is more improved.
-
product
Oil Tangent Delta Tester
MG-I
Chongqing Kailian Yongrun Industrial Co.,Ltd.
It is designed to test dielectric loss factor(tangent delta tgδ) and capacitance of transformer oil, capacitor oil, cable oil and other insulation oils.
-
product
Oil Immersed Test Transformer
SG-YD
Wuhan Sangao Electrical Test Installations Limit Co.
AC and DC test oil immersed transformer.Traditional oil immersed test transformer is used to do power frequency withstand voltage and DC current withstand voltage test for variety kinds of high voltage electric device, insulating material.YD series oil transformer, also known as test booster, which test insulation strength under specified voltage for various electric products, components, insulation materials. It can test products insulation level, find insulation defect and judge overvoltage ability. It is widely used in power station, power supply and distribution system and research institute.
-
product
Reactors
Chengdu Mengsheng Electronics Co., Ltd.
Reactors (also called inductors) are key power equipment used to regulate current, voltage and harmonics, and are widely used in power transmission, distribution systems and power electronic equipment. Our reactor products include single-phase reactors, three-phase reactors, air-core reactors, iron-core reactors and, which can meet the needs of different application scenarios. Designed and manufactured with high-quality metal materials and insulating materials to ensure high efficiency and safety and stability, and provide a variety of cooling methods such as natural cooling, forced air cooling and oil immersion cooling, suitable for various environmental conditions. With excellent performance and reliable quality, our reactor products can effectively improve the stability and reliability of the power system and meet the stringent requirements of modern power systems.Browse our electrical reactor products, if you need customization, please contact our team.
-
product
Oil Tan Delta Tester
Weshine Electric Manufacturing Co., Ltd
The Oil Tan Delta Tester (OTD) is a laboratory instrument, which measures the Tan Delta, Resistivity and Relative Permittivity of insulating liquids. These tests give a wider picture of the overall quality of the insulating oil, and will indicate if there is any contamination. WESHINE has developed features of the OTD to ensure that productivity levels within laboratories are maximised.
-
product
Insulating Oil Testers
The main functions of electrical insulating oils are heat dissipation and reliable insulation of energised parts of electrical installations. During the normal operation, moisture and other impurities penetrate into insulating oils, leading to a deterioration of their dielectric properties. This in turn may result in catastrophic failures of critical electrical equipment.
-
product
Insulating Oil Dielectric Loss Tester
HDLT
Hention Electrical Equipment Co., Ltd.
This integrated precious insulation oil dielectric loss tester is for measuring dielectric loss TAN and capacitance of transformer insulation oil.This is a high precision instrument; integrated with oil cup, temperature control instrument, temperature sensor, dielectric loss test bridge, AC test power, and standard capacitor, etc.
-
product
Wet-Mateable Connector, 10k V, 250 A
Nautilus WM10-250
Trends in subsea oil & gas production are moving towards deeper water and longer step out distances. These trends drive demand for higher power equipment and higher power delivery and distribution capabilities subsea with high pressures and temperatures. Teledyne ODI'™s Nautilus WM10-250 is designed with the benefit of advanced material science testing and certification, and with insulation and redundant sealing systems for reliable performance in long-term harsh environments.
-
product
Oil Tan Delta Test Set
The Oil Tan Delta (OTD) is a laboratory instrument, which measures the Tan Delta, Resistivity and Relative Permittivity of insulating liquids. These tests give a wider picture of the overall quality of the insulating oil, and will indicate if there is any contamination. Megger has developed features of the OTD to ensure that productivity levels within laboratories are maximised. OTD test sets are supplied with sixteen standard test sequences pre-installed, to support a set of international standards.
-
product
GDGY Insulating Oil Tangent Delta Tester
Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd
It is applied to measure dielectric loss angle and Volume Resistivity of insulating oil etc.
-
product
Moisture in Oil Transmitter
KT-200
Kongter Test & Measurement Co., Limited
KT-200 is a fast, reliable and accurate online transmitter for water activity (aw) in oil and temperature (T). It is very suitable for integration in OEM application with its rugged housing and excellent performance.KT-200 is ideal for online monitoring of moisture in lubrication, hydraulic or insulation oil, which is significant for the long-term performance and preventive maintenance of plant and machinery.
-
product
Transformer Oil Dielectric Breakdown Voltage Tester
MG-II
Chongqing Kailian Yongrun Industrial Co.,Ltd.
The dielectric breakdown voltage test (BDV test) is an important test to determine the breakdown voltage of insulating oils. After a certain period, transformer oil will be degraded, and there are moisture, gas and impurity in oil. Then, the quality of transformer oil is affected. So it is necessary to test the transformer oil. BDV test is one of the most common tests to insulating oils.
-
product
OIP TYPE VOLTAGE TRANSFORMER
12kV - 145kV post type voltage transformers having Oil Impregnated Paper( OIP) as major insulation has been designed with several unique features.OIP insulated outdoor products are subjected to extreme climatic conditions and hence extra care is taken in the design and manufacturing of such transformers.
-
product
Electric Insulation Oil Automatic Measurement System
DAC-5016
DAC-5016 is an automatic test system of insulation oils according to JIS C-2101.The system automatically enables changing over samples (liquid cells) up to max 8 pieces and testing the dielectric loss tangents and the volume resistivities.In automatic mode, the dielectric loss tangents and the volume resistivities are automatically measured, and then the results are printed out with the built-in printer. And the relative permittivities and the volume resistivities calculated are also printed out. Therefore the test time is greatly saved compared to the conventional test methods.
-
product
Dielectric Strength Meter
Dielectrotest
The Dielectrotest is a fully automatic dielectric oil meter for determining the breakdown voltage of insulating liquid. It is designed for both laboratory and field use for commissioning and maintenance purposes. The test standard is selected via menu.