Filter Results By:
Products
Applications
Manufacturers
- Taylor Dynamometer, Inc.
product
622 HP Eddy Current Chassis Dynamometer
CM-51-EC
Weight Capacity: 25,000 lb (11,340 kg) per axleRoll Brakes: pneumatically-actuated discShipping Weight: 8,340 lb (3,783 kg)Capacity: 622 hp at 45 mph (464 kW at 72 kph)Rolls: 20 by 36 in. (508 by 915 mm) long4 front fixed rolls, 2 rear rolls fixed toaccommodate axle spreads from48 to 60 in. (1,219 to 1,524 mm)tandem centersPit Required Depth: 25 in. (635 mm)
-
product
HIGH FREQUENCY DC BIAS
6565 SERIES
The 6565 HF DC Bias Unit is intended to be used with a Wayne Kerr 6500 analyzer, either the 6500B Precision Impedance Analyzer or the 6500P HF LCR Meter. Its function is to provide a source of DC bias current through the Device Under Test (DUT) while the analyzer is making AC measurements. Each 6565 unit can provide up to 10 A of DC current, and up to six 6565 units can be connected in parallel to supply a maximum 60 A. A digital ammeter on the front panel allows the user to see the dc bias current value and an indicator LED shows when the bias current is enabled.
-
product
Dual Channel, Low-Noise DC Bias Card
PI-41701
The PI-41701 is a dual channel bipolar DC Bias supply that can provide an output current up to 100 mA per channel. The output voltage ranges from –8 V to +8 V and features programmable current limits with LED indicators and software interrupt to show/alert the user if the channel is in current limit. This card has special filter circuitry to reduce the output noise for those applications that require a low noise bias output.
-
product
DC Bias Current Source
FD1772B
• Constant DC output 0-6A• Auto or manual current sweep output• 5 current range output• Output voltage range: 0-11.5V• Current accuracy ± (1%reading + 2digit)
-
product
Operational Amplifiers
Operational amplifiers from ams are ideally suited to audio applications. These CMOS devices are available as single, quad or differential amps. They feature good common-mode rejection, have low input bias currents, good gain bandwidth, low total harmonic distortion and an excellent rail-to-rail output-drive capability of 200mA peak.
-
product
Precision Current Preamplifier
SIM918
Stanford Research Systems, Inc.
The SIM918 Current Preamplifier is ideal in applications in which the input offset voltage must be kept to a minimum. The DC voltage difference between the two inputs (current input and voltage bias) is accurately measured every 2 seconds, and is nulled.
-
product
O/E Converter
TIA-4000
The TIA-4000 is comprised of a fibre coupled InGaAs APD detector combined with a variable reverse bias voltage network and fast transimpedance amplifier. The output of the unit is brought out to a type K female SMA connector. Light falling on the detector generates a positive-going proportional current. This current, multiplied by the transimpedance produces a voltage that is proportional to the light incident on the detector surface.
-
product
DC Bias Current Source
DU2020/2030/2040
Delta United Instrument Co., Ltd.
Frequency: 10KHz - 200KHz Veracity:3% + 3 digitsTiming: 0.1 - 999 H, settable 3 1/2 bits LCD Display
-
product
PIN Diodes
PIN photodiodes convert light to current – without a bias voltage having to be applied. Silicon is commonly used as an inexpensive detector material in the Vis range. For higher demands, InGaAs is used; it covers the widest spectral range from the Vis to the NIR. We offer silicon carbide as a “solar-blind” detector specifically for the UV range.
-
product
8-CH 24-Bit High-Resolution Dynamic Signal Acquisition Module
PCIe-9529
The ADLINK PCIe/PXIe-9529 is a high-performance, high density, 8-CH analog input dynamic signal acquisition module. The PCIe/PXIe-9529 features eight 24-bit simultaneously sampling analog input channels. The 24-bit sigma-delta ADC provides a sampling rate of 192 kS/s at high resolution, making it ideal for higher dynamic range signal measurement. All channels are sampled simultaneously and accept input range up to ±10V, and the analog inputs support software-selectable AC or DC coupling and 4 mA bias current for integrated electronic piezoelectric (IEPE) sensors. The module is especially designed to meet the requirements of vibration analysis and audio testing.
-
product
Low Input Bias Current Amplifiers (<100 pA)
Low input bias current op amps are required whenever the difference of currents or voltage is small and needs to be measured accurately. These op amps are used so that the signal is not loaded down by the input of the op amps. Low input bias current op amps are critical for interfacing sensors in applications from photodiodes, pH meters, or other electrometer related functions to downstream electronics. Analog Devices has many precision op amps that fit the definition and range of these applications.
-
product
Versatile quality control testing system
QuickSun® 550Ei
QuickSun 550Ei is a versatile testing system for qualifying of PV modules with dimensions up to 105 x 205 cm2. Basic set up includes a top class solar simulator which measures modules in sunny side up position enabling e.g. soiling simulations. Several additional measurement methods can be integrated to the same system including high resolution EL imaging with analysis software from one of the most recognized EL system suppliers. Also hot spot revealing IR images can be recorded by applying either forward or reverse bias current, and true nA scale leakage current measurements can be performed with sensitive enough instruments.
-
product
Linear Regulators
It is designed to operate from a single input supply with an input voltage as low as 1.10 V without the requirement of an external bias supply to increase efficiency and provide up to 5 A of output current (IOUT).
-
product
24-Bit High-Resolution Dynamic Signal Acquisition and Generation Module
PCI-9527L
The PCI-9527L is a high-performance, 2-CH analog input and 2-CH analog output dynamic signal acquisition board. This board is specifically designed for audio testing, acoustic measurement, and vibration analysis applications.The ADLINK PCI-9527L features two 24-bit simultaneous sampling analog input channels. The 24-bit sigma-delta ADC provides a sampling rate up to 216 KS/s at high resolutions, making it ideal for higher bandwidth dynamic signal measurements. The sampling rate can be adjusted by setting the onboard DDS clock source to an appropriate frequency. All channels are sampled simultaneously and accept an input range from ±40 V to ±0.316 V. The PCI-9527L analog input supports software selectable AC or DC coupling and 4 mA bias current for integrated electronic piezoelectric (IEPE) sensors.
-
product
Military-Style DC Solid-State Relay for High-Current Pulse Load Applications
Part No. M33-2N
The M33-2N is a military-style DC solid-state relay designed for high-current pulse load applications. It features the latest power FET output technology to minimize ON resistance. This feature provides minimum output voltage drop and allows the M33-2N to switch high pulse currents up to 100 amps at higher temperatures than those allowable with bipolar devices. The M33-2N utilizes transformer isolation to protect against transients, and are through-hole mountedMSL 1 Available options include:M33-2 7Adc, 60Vdc Load; 4.5-5.5Vdc (bias voltage), 80µA (CMOS) Control;
-
product
Software
Current-Voltage Measurement Option
Materials Development Corporation
CSM/Win Systems with an I-V option can measure both MOS and diode structures. For junctions, both forwardand reverse bias curves can be analyzed. Junction ideality factor, series resistance, and reverse saturation current are found. Solar cells can be checked for efficiency. Gate Oxide Integrity of MOS devices can be measured as well.
-
product
High Current Probes
*Low internal resistance to minimize arching*PogoPlus bias ball design*High current optimized base material and plating*Higher temperature spring design*Specialized high current tip geometry
-
product
8-CH 24-Bit High-Resolution Dynamic Signal Acquisition Module
PXIe-9529
The ADLINK PXIe-9529 is a high-performance, high density, 8-CH analog input dynamic signal acquisition module. The PXIe-9529 features eight 24-bit simultaneously sampling analog input channels. The 24-bit sigma-delta ADC provides a sampling rate of 192 kS/s at high resolution, making it ideal for higher dynamic range signal measurement. All channels are sampled simultaneously and accept input range up to ??10V, and the analog inputs support software-selectable AC or DC coupling and 4 mA bias current for integrated electronic piezoelectric (IEPE) sensors. The module is especially designed to meet the requirements of vibration analysis and audio testing.
-
product
RF Amplifiers Bias Controllers
RF amplifier bias controllers generate a regulated drain voltage and actively adjusts the gate voltage of an external amplifier to achieve constant bias current. It can be used to bias any enhancement and depletion type amplifier operating in Class-A regime with drain voltages (VDRAIN) as specified. These devices achieve excellent bias stability over supply, temperature and process variations, and eliminates the required calibration procedures used to prevent RF performance degradation due to such variations.
-
product
50Hz-100kHz LCR Meter
11022/11025
Chroma Systems Solutions, Inc.
0.1% basic accuracyTransformer test parameters (11025), Turns Ratio, DCR, Mutual Inductance0Hz, 60Hz, 100Hz, 120Hz, 1kHz, 10kHz, 20kHz, 40kHz, 50kHz, 100kHz test frequencies21ms measurement time (≥100Hz)Agilent 4263B LCR Meter commands compatible4 different output resistance modes selectable for non-linear inductor and capacitor measuringHigh resolution in low impedance(0.01mΩ) and high accuracy 0.3% till 100mΩ rangeAdjustable DC bias current up to 200mA (constant 25Ω) (11025)1320 Bias Current Source directly control capability0.01mΩ ~ 99.99MΩ wide measurement range (4 1/2 digits)Dual frequency function (11022 option) for automatic productionBIAS comparator functionComparator function and 8/99 bin-sorting functionPass/fail judge result for automatic productionHandler interface trigger edge (rising/falling) programmableTest signal level monitor functionStandard RS-232, GPIB, and Handler I/FOpen/short zeroing, load correctionLabView® Driver
-
product
DC Current Bias Supply
DC1000A
To guarantee the quality and performance of inductive components such as inductors, chokes and transformers they are tested at their real-life operating point. If the inductor is designed to carry a DC current, then its inductance must be measured with that DC current present. Until now, these measurements were made by an LCR meter connected via special interfacing to a DC bias supply available only from the manufacturer of the LCR meter. The unique NEW DC1000A can be used with any precision LCR meter and connects simply into existing test fixturing.
-
product
JFET Input Amplifiers
Analog Devices JFET input op amps or FastFET high speed (>50 MHz) input op amps provide high input impedance and ultralow input bias currents for high speed applications. The majority of our FET input op amps feature wide supply ranges from +5 V to 12 V or higher and feature rail-to-rail outputs enabling wide dynamic range.
-
product
K-Band Waveguide Gunn Oscillator Module
FMWGN1001
FMWGN1001 is a K Band Waveguide Gunn Oscillator with a Center Frequency of 24.125 GHz and a Tuning Range of +/- 1.0 GHz. The unit has a Phase Noise @ 100kHz Offset of -95 dBc/Hz typ and Frequency Stability of -0.4 MHz/°C max. The Gun Oscillator has an Output Power of 10 dBm min and Power Stability of -0.04 dB/°C max. The Waveguide Gun Oscillator uses a Bias Voltage of 5.0 Volts and a Bias Current of 200 mA and has a Waveguide Size of WR-42 with a UG-595/U Flange.
-
product
High-Power Low-Loss Pulsed Bias Tees
MBT series
The MBT-series of bias tees is based on Maury's patented broadband capacitor (US Patent 9,614,267) which simultaneously enables the industry's widest bandwidth, lowest insertion loss and lowest return loss in a coaxial bias tee up to 18 GHz. In addition, its unique design makes it ideal for pulsed applications, including pulsed IV and pulsed load pull characterization, without distorting the voltage and current waveforms.
-
product
DC Bias Current Power Supply
TH1775
Shenzhen Chuangxin Instruments Co., Ltd.
TH1775 is a DC Bias Current Source (or DC Magnetization Current Source) used for inductance measurement of inductors and transformer windings with DC bias current. Except for constant current output, low additional error and wide frequency response range are important for bias current inductance measurement. High frequency LCR meter could be used, when the frequency response range is wide enough. MPU controlled auto current balance technology is adopted to realize AC+DC current overlap and constant current output from 0 to ±20A. Two TH1775 can be paralleled to supply a maximum current up to 40A.TH1775 permits high frequency measurement up to 1 MHz and can be directly controlled by TH2816A, TH2817A, TH2818 and TH2819. TH1773/TH1775 with its low additional error, wide frequency response range and sweep output function is widely used in DC biased inductance measurement. TH1775 also provides a perfect solution for magnetic material analysis.
-
product
SPA100
Our highly sensitive source picoammeter is designed for measuring and logging very small currents down to the pA range - making it an ideal instrument for scientific and research applications, including physics, materials science and electron microscopy. Full-featured at an affordable price, the SPA100 combines sensitivity, accuracy and stability to allow users to measure low currents with high precision as well as conveniently source bias voltages for experimentation. SPA100 also doubles as an ultra-high resistance meter, measuring accurately into the teraohm range. As with all our “headless” products, the SPA100 connects to PC via USB and utilises our complimentary software EPIC - enabling users to easily measure, graph and capture readings with timestamps and measurement stability information.
-
product
DC BIAS CURRENT UNIT
3265B SERIES
To evaluate components at currents up to 125 A the 3265B DC Bias Units are used with either the Wayne Kerr 3255B series of Inductance Analyzers or the 3260B Precision Magnetics Analyzer. When one 3265B/25A or 3265BQ/25A DC Bias Unit is connected to an instrument up to 25 A of DC bias current can be set in steps of 25 mA with one unit. Additional DC Bias Units can be added such that with five units connected in parallel it is possible to set DC bias currents up to a maximum of 125 A DC.
-
product
High Output Current Op Amplifiers ≥ 100mA
Analog Devices high speed , high output current (≥100 mA) op amps deliver high output current while driving low impedance loads with excellent linearity. Whether it's high output current, low input bias current, wide bandwidth, high slew rate, or low distortion, no one sets more performance standards for next-generation designs with the widest portfolio of leading edge products than Analog Devices.
-
product
PRECISION MAGNETICS ANALYZER
3260B SERIES
At the design stage of component development it is vitally important to understand how the component performs under different operating conditions. This might include operation at diverse frequencies, AC drive levels or DC bias currents.
-
product
Micro probes 1 MHz up to 6 GHz
MFA 01 set
The micro probes are used to measure magnetic fields and they have a high resolution. They measure magnetic fields up to 6 GHz, e.g. at signal conductors (150µm), SMD components (0603-0201) or IC pins. The MFA micro probes are guided by hand. An amplifier stage is integrated into the probe head. The amplifier stage (9V, 100mA) is powered via the Bias tee BT 706. It has an impedance of 50 Ohm. The micro probes are connected via the Bias tee BT 706 to a spectrum analyzer or an oscilloscope. Langer EMV-Technik GmbH includes correction lines in the delivery. With the help of the correction lines the probe output voltage is converted either into the respective magnetic field or to the current which is running through the conductor.
-
product
Low Input Bias Current Op Amps (≤100 pA)
Low input bias current op amps are required whenever the difference of currents or voltage is small and needs to be measured accurately. These op amps are used so that the signal is not loaded down by the input of the op amps. Low input bias current op amps are critical for interfacing sensors in applications from photodiodes, pH meters, or other electrometer related functions to downstream electronics. Analog Devices has many precision op amps that fit the definition and range of these applications.