Filter Results By:
Products
Applications
Manufacturers
- Pickering Interfaces Inc.
product
PXI Mixed Configuration Relay Module - 1 Cell Populated
40-138-AA-BB-CC-DD (1 CELL)
The 40-138 2A Relay Module with 1 cell populated is a cell-based mixed configuration switching module suitable for applications requiring medium power switching with high density. It provides a broad selection of mixed relay types for greater flexibility and features 2A current capacity and voltages to 300VDC/250VAC.
-
product
Reference Cells
Reference cell is used for measuring and setting the intensity of solar simulators for one sun (or other user desired) intensity condition. They are also used to calibrate the IV Measurement system photo-detector intensity to match the measured ISC to calibrated ISC.
-
product
Solar Reference Cell
The Solar Reference Cells consist of a 20 mm x 20 mm monocrystalline silicon Photovoltaic Cell encased in a 92 mm x 70 mm x 16 mm metal enclosure with a protective quartz window and a temperature sensor. Designed for calibrating the irradiance of solar simulators used for testing solar cells and modules.
-
product
Spectral Response SystemsQuantum Efficiency SystemsIPCE Measurement Systems
QE system provides electronics and software designed for fully automated measurement of external quantum efficiency of solar cells. All systems include probes and a fixed plate sample stage for samples up to 150 mm x 150 mm. The main system components include: custom designed software, measurement electronics, and computer system (Windows 8 operating system). The measurement involves focusing monochromatic light to a spot on the device under test, then accurately measuring the photon flux and current from the test cell. The system utilizes a dual beam configuration with lock-in detection, providing an absolute accuracy of ±3%. The QE system uses a grating monochrometer with silicon/InGaAs/Ge detectors. The system includes automatic order sorting filters and two light sources for monochromatic illumination (a Xenon- arc lamp and a halogen lamp). A single lock-in amplifier is used to measure both the reference detector and test device. The main system comes with all the hardware needed to measure quantum efficiency, a fixed plate sample stage and probes.
-
product
Power Meters and Calibration Cells
The Solar Reference Cell consist of a 20 x 20 mm monocrystalline silicon Photovoltaic Cell encased in a 92 x 70 x 16 mm metal enclosure with a protective quartz window and a temperature sensor. The temperature sensor is a 100 ohm platinum Resistance Temperature Detector (RTD).The Solar Reference Cells come with a Certificate of Calibration and compatible set of connecting cables. The following parameters of the reference cell are certified: Isc, Imax, Voc, Vmax, Pmax, Area, Fill Factor and Efficiency. The certification is accredited by NIST to the ISO-17025 standard and is traceable both to the National Renewable Energy Laboratory (NREL), and to the International System of Units (SI). A compatible cable set is also supplied with each Solar Reference Cell.
-
product
Solar Monitoring Stations
EKO Instruments unique Solar Monitoring Station (SMS) is the primary reference to collect high quality solar irradiance data on-site. The innovative turn-key system provides all fundamental solar radiation and meteorological parameters for PV site evaluation, performance monitoring and cell optimizing.
-
product
Calibrated Solar Reference Cell
To insure repeatable testing on any solar simulator, OAI offers 2cm x 2cm calibrated reference cells. Standard reference cell calibration cycles can be set up by OAI''s calibration laboratory to insure that your reference cell maintains certification.
-
product
Solar Cell I-V Characterization System
VS6821
Industrial Vision Technology Pte Ltd.
This system provides cell manufactures and laboratories a new way in testing and measuring photovoltaic cells. Integrated with Steady-State Solar Simulator, it provides complete coverage of testing parameters and measurement requirements by most international standards. Its test methods, procedure & equipment are IEC 60904 compliant. Calibration of reference cell is performed at Fraunhofer ISE in Germany, and is traceable to PTB.
-
product
Reference Cells For PIV-IV Systems
NREL calibrated cell used for calibration transfer.The Abet Technologies solar reference cell is a precision instrument for the determination of solar simulator irradiance levels. The sensor is a mono-crystalline silicon solar cell having an area of2x2cm(4cm).The back of the solar cell is attached to the device in such a way that a good heat transfer to the device housing is guaranteed. Below the solar cell a Pt100 RTD temperature sensor is mounted to allow monitoring of device temperature. The device is not shunted allowing the whole IV-curve to be measured. The solar cell is protected by a high quality fused silica window, assuring spectral sensitivity over a 320 -1100 nm range.
-
product
Solar Cell Testers
Solar Cell Testers are integrated systems incorporating Solar Simulator and I-V Measurement systems. PET offers Standard and Advance IV Measurement software. PET Cell Testers are capable of measuring a diverse range of solar cell parameters such as Isc,Voc, Imax,Vmax, Pmax, FF, Rsh, Rs and η cell conversion efficiency, complete light and dark I-V curves. All that needs to be done to test a cell is to load the cell, make electrical probes contact and press “Measure” icon on the I-V Measurement System software. The software will automatically open the Solar Simulator shutter, perform the test and close the shutter after the test is complete. The design is modular in nature and can be easily upgraded. Some options can added at a later time.
-
product
Light I-V Testing for Solar Cells
FCT-650
Advanced analysis of solar cells including light I-V and Suns-Voc data.
-
product
Direct Burial Half Cell Reference Electrode
DB-A
Model DB-A Copper-Copper/Sulfate Reference Electrode designed for direct burial for long term monitoring of buried or earth contacting structures.
-
product
NI Real-Time Test Cell Reference System
780590-35
VeriStand Full Development License with NI Standard Service , Include 1 Year SSP
-
product
SOLAR CELL TESTER
The tester is designed for terrestrial solar cell incoming/outcoming inspection with the purpose of checking and optimizing parameters and preventing manufacture defects of solar modules. Solar cells are not heated in process of inspection due to the use of xenon pulse lamp installed in the tester.
-
product
Solar Simulator for Multijunction Solar Cells
For series connected multijunction cells, at a given spectrum (e.g. AM 1.5 or AM 0 for space solar cells), one of the cells will limit the current in the series connection of cells. All solar simulators deviate from the true AM 1.5 spectrum, and they are only classified in wide spectral bands (100nm width). So even for class A or A+ solar simulators, it can easily happen that the bandgaps of the multijunction cells are such distributed that the 'wrong' cell will limit the current, if a solar simulator with fixed spectrum is used. In the 70s and 80s, when these measurements were first developed, intercomparisons showed deviations of cell efficiency in fixed spectrum solar simulators of more than 40%.
-
product
Solar Cell Systems
he Solar Cell Scan is a multifunctionalexperimental platform,which is based on the measurement of Quantum Efficiency (QE) . The system employs a turnkey integrated design, which can carry out QE, Reflectivity and Mapping testing functions automatically. There are also modular and customdesigned accessories to adapt to different solar cell samples.
-
product
Reference Supplies
Advanced Energy's Trek reference supplies offer both high temperature and time stability outputs. They can also be used as a secondary traceable standard.
-
product
Reference Sources
A physical or digital document that you would refer to for more information about a topic.
-
product
Solar Simulator
Unisim
TS-Space Systems is the first company to pioneer the use of metal halide sources in solar simulators for photovoltaic testing. The high temporal stability and close spectral match combined with the ability to control the output spectrum via multiple separate wavebands means the Unisim solar simulator is the only solar research tool designed for the accurate measurement of multiple junction devices, including the new generation of four junction devices. As with all our Unisim solar simulators, they exceed the ASTM, IEC and JIS international standards for spectral match and temporal instability. Using the latest HMI and halogen luminaire technology, the Unisim solar simulator provides a highly stable area of illumination. The simulators also use cutting edge filter technology in order to provide the best spectral match available for AM0 and AM1.5. Further to this, the spectrum can be achieved via two, three or four separate spectral wavebands which allows a high degree of spectral control for research and development. Product support is very important to us. Training is provided at our premises where customers can take advantage of one-on-one tuition with the instrument designers and learn how to operate and maintain their tools. Extensive support via phone and email for the full lifetime of the instrument is included with every TS-Space Systems product.
-
product
Solar Simulator
PEC-L15
●Light source/lamp house integrated compact design●Irradiation head rotates (downward, upward, sideways irradiation possible)●5cm square optical filter can be attached●Equipped with high-speed shutter (100ms)●Body weight is only 16kg.
-
product
Reference Standard
Beijing GFUVE Electronics Co.,Ltd.
It has been designed for universal laboratory and test applications and is intended for checking and the calibration of reference standards for electrical power and energy.
-
product
Cell Solar Simulator
QuickSun® 130E
QuickSun 130E exceeds the ordinary Class A criterions of IEC904-9 ed. 2 with clear margin providing enhanced IV characteristics accuracy. The applicable test methods and procedures are inspected by SGS Fimko Ltd in order to guarantee the compliance and traceability not only with the above standard but also with IEC904-1 ed. 2 which specifies the IV measurement conditions.
-
product
Reference Voltage Measurement Cell
C-80
Cells C-80 and C-100 are used as reference devices for measuring voltage during calibration and adjustment of OLT-series testers.
-
product
SolarIV Series Solar Cell Current Voltage Measurement System
SlarIV
SolarIV IntroductionOne of the key measurements needed for photovoltaic devices in the measurement of their I-V characteristics. Through measuring the I-V curves the user can determine physical performances of devices such as photo-electric conversion efficiency, fill factors and so on. Such data is important for reliable work in research and quality inspection. ZOLIX supply the SolarIV system and the most perfect, professional technical support.
-
product
Reference Magnets
Reference Magnets provide a stable and convenient method to verify the accuracy and calibration of Hall Effect Gaussmeters, Teslameters, and Probes.
-
product
NI Real-Time Test Cell Reference System
778820-35
DIAdem Advanced with DAC Bundle, Perpetual License, Include 1 Year SSP
-
product
Solar Simulator
Jiangsu Keyland Laser Technology Co., Ltd.
Features:- Beyond Class AAA performance- Stable continuous working- 8000 data collecting points- Durable flash lamp- Voice prompt- Measuring data export- Customizable for special panels
-
product
Solar Analyzers
Max. solar system power (Pmax) search by Auto-scan: 1000V, 12A (12000W capability)The analyzer and the Remote Solar Detector is connected by Bluetooth wireless communication (Bluetooth 2.1 + EDR Class 1)The Remote Solar Detector is moisture-proofIntelligent test logic with no personnel attendance required in the field Solar system analyzer waits and tests the system until appropriate sunlight irradiance is detectedMax. voltage (Vpm) at Pmax, Max. current (Ipm) at Pmax Voltage at open circuit (Voc), Current at short circuit (Isc)Efficiency (%) calculation of solar systemTemperature measurement of solar panelsIrradiance measurement of sun lightSeries resistance (Rs) calculation of solar panelsWith data logging/open function, the I-V curves of solar system can be analysed / recorded for a period of time (e.g. 60 min.)Conversion of I-V curve under OPC to data under standard test condition (STC) based upon IEC standardProvide Operating Condition (OPC) and Standard Test Condition (STC) test reports for verification of solar panel performance (OK or NO OK)Users can set up the parameters of solar panelsUsers can set up the series number of solar panels. Parameters of many solar panels can be measured in one measurementThe Irradiances and Temperatures of solar panels can be continuously measured, monitored and recordedContinuously measure/monitor/record the DC power output of solar system and the AC power output of inverter (1 phase or balanced 3 phases)Calculate the efficiency of DC to AC power conversion and the efficiency of the max.output power
-
product
Reference Antennas
Type NRD
Reference antennas are precision dipole antennas that offer a fixed 2.15 dB of gain over an isotropic antenna along the major lobe axis at specified frequencies (2.15 dBi). They are intended to be used for antenna field pattern and gain measurements, or general RF sensing in the laboratory.