ALS Co., Ltd
ALS provides researchers with a wide range of products for electrochemistry and spectroelectrochemistry applications, including Bi-Potentiostat (Model 2325), Ring-Disk Electrode apparatus (RRDE-3A), Spectrometer Systems (SEC2000) and Faraday cage (CS-3A).
- sales@als-japan.com
Tokyo,
Japan
-
product
Conductivity Electrode
As current-carrying and potential difference measuring electrodes, platinum was deposited on a quartz glass substrate. Voltage terminal distance can be varied by changing the connection pin. In-situ measurement of the metal transition produced in a conductive polymer insulator doping, 4 terminal electrode is used, where for insulator layer with low doping side 2 terminal method and for metal layer with high doping side 4 terminal method is used for the measurement. With this electrode, become possible to have measurement in 15 distances by combining the connection terminal.
-
product
Bulk Electrolysis Cell
This cell has been developed in order to perform a complete electrolysis. The carbon working electrode is a reticulaed form that provides with sufficient surface area to gain the rate in electrolysis.
-
product
Flow Cell Kit
EQCMT
The two blocks of the EQCMT Flow cell are constructed using PEEK. It gives a high resistivity for chemical compounds.As well as QCM, these cell is reversible. With a inverted position of the blocks, it is possible to change from flow to static measurement.
-
product
Rotating Ring Disk Electrode
RRDE-3A
RRDE-3A is a constant rotation system for use in hydrodynamic modulation rotating ring disk electrochemistry. A 7 mm diameter electrode with short stainless steel shaft provides for a miniature and concentric circle electrode system that is capable for highly accurate rotation and modulation even at radial modulation rates or wave forms.
-
product
Voltammetry Cell
SVC-3
By using this cell, researchers can run experiments free from gasificationed steam. Also, researchers can get rid of influence of oxygen in the cell by bubbling nitrogen gas. This cell can be utilized with CS-3A Cell Stand. This feature is well suited for measurements of ultraweak current.
-
product
Flow Cell Kit
QCMT
The quartz crystal microbalance (QCM) technique under electrochemical frequency is very useful to determine many compounds such as metal proteins, metal ions and thiol-conjugated oligonucleotides.
-
product
Plate Material Evaluating Cell
This quite handy cell is developed in order to evaluate plate material such as metal, semi-conducting plate, etc. In evaluation, a sample plate is sandwiched between cell blocks.
-
product
Working Electrodes for Flow Cell
Our working electrodes for flow cell are mounted in blocks of PEEK. This resin protects the electrodes from external noise and allows researchers to utilize them regardless the content of mobile phase of HPLC because of their hardness and organic slovent-resistance. Glassy carbon is usually chosen for the redox reaction study on liquid chromatography. Platinum, Gold, Carbon paste and Nickel electrodes are utilized for special purporses.
-
product
Radial Flow Cell
The wall jet of the sample, after hit in to the surface of the electrode, spreads in three dimensions. After hitting the sample on a thin layer electrode directly, it flows to the perimeter from the center of the radiated electrode, improving the sensitivity.
-
product
Voltammetry Cell
VC-4
Capable for measuring of 1 - 3 ml of sample volume using electrodes with 6 mm of the diameter. Furnished holder prevents the vial from spilling.
-
product
ITO (Indium Tin Oxide) Electrode
This quite unique material transmits only visible light whereas it does not transmit UV radiation. Our ITO electrodes consist of 100 nm thick of ITO layer deposited on quartz or borosilicate glass substrate (0.5 mm thick).
-
product
Reference Electrodes
Reference electrodes are widely used as: electrochemical measurements (CV, LSV, DPV, etc.) electrochemical devices (detectors for HPLC, biosensor, etc.)
-
product
Cross Flow Cell
Working electrodes for flow cell are mounted on blocks of PEEK. This resin protects the electrodes from external noise and allows researchers to utilize them regardless the content of mobile phase of HPLC because of their hard, organic solvent-resistance. Glassy carbon is usually chosen for the redox reaction study on liquid chromatography. Platinum, Gold, Carbon paste and Nickel electrodes are utilized for special purposes. Thin Layer Cell has been used as a electrode for research such as flow injection analysis (FIA) and the HPLC.
-
product
Oxygen-free Voltammetry cell
SVC-3C
By using SVC-3C oxygen-free Voltametry cell, researchers can get rid of influence of oxygen in the cell by bubbling nitrogen gas, and also run the experiments at low temperatures.
-
product
Grid Electrode
Grid electrode is produced by the deposition of the platinum, gold or carbon onto the quartz glass. The dimension of the glass is 8 x 27 mm, with a 1 mm of the thickness, and the grid line is 100 m width with a distance of the 150 m between lines.