IBEKO Power AB
Our goal is to always keep providing the world market with the most advanced test solutions for transformers, circuit breakers and batteries
- +1 800 599 8113
+46 70 0925 000 - +46 8 731 77 99
- sales@dv-power.com
- Box 1346
Lidingö, 181 25
Sweden
-
product
Battery Extra Load Units
Performing capacity/discharge test on a high-capacity battery may be challenging since high requirements are set on the discharge system. In cases when discharge test times need to be reduced, high load capacities are required from the discharge system. The battery extra load unit BXL is an additional load unit designed especially for this purpose.It is primarily used with BLU battery testers. However, the unit is a universal add-on device. This means it can be used as an additional load with any other discharge/capacity tester in the market.When discharge current exceeds the capacity of a single BLU device, extra load unit increases discharge capacity. A system of BLU and BXL instruments enables performing the capacity test in an accurate, user-friendly way in accordance to battery testing standards: IEEE 450-2010, IEEE 1188-2005, IEEE 1106-2015, IEC 60896-11/22, and other relevant standards.
-
product
Coil Analyzers
SAT Series
The Coil Analyzers SAT30A and SAT40A are powerful, lightweight units ideal for testing of circuit breakers. Substation battery is not connected or available. The SAT series instruments are intended to supply circuit breaker coils and spring charging motors. They spring charging motors (SAT40A – AC and DC) as a part of commissioning and maintenance testing.
-
product
Handheld Micro-Ohmmeters
RMO-H Series
The RMO-H is battery operated and handheld micro-ohmmeter. It is designed for a variety of applications for contact resistance measurement of non-inductive test objects. Typical applications are accurate testing of:medium and high-voltage circuit breakers,disconnecting switches,high-current bus bar joints,cable splices,and different high-current links.Even more, it accurately measures in high-induction filed environments and substations, as well as in factory testing.RMO-H Series contains six models in total, divided in 2 sub-series depending on the test leads length requirement and the battery type:RMO-H1, RMO-H2 and RMO-H3 models are intended for use with short cables (e.g. 1,3 m / 3 m / 5 m). The 1-cell Li-Po battery with 8200 mAh capacity provides output voltage up to 4,1 V DC.RMO-H21, RMO-H22 and RMO-H23 models are ideal for applications where test leads with lengths > 5 m are required. The high output voltage (up to 8,3 V DC) is provided by 2-cells 4100 mAh Li-Po battery.The test current is regulated and can be selected in a range of 1 A to maximum 300 A, depending on the maximum test current rating:RMO-H1, RMO-H21 models – up to 100 A DCRMO-H2, RMO-H22 models – up to 220 A DCRMO-H3, RMO-H23 models – up to 300 A DC.Unlike many other handheld micro-ohmmeters available on the market, our instruments have regulated and user-selectable test currents. Therefore, RMO-H instruments generate an automatically regulated test ramp with stable and ripple-free current during measurement. These revolutionary characteristics in a handheld micro-ohmmeters technology are possible by using sophisticated Li-Po batteries. Consequently, modern battery technology enables you to do multiple measurements, and a full day of testing without recharging the battery.With all RMO-H models, it is possible to make tests on Both Sides Grounded testing objects, in an increased safety environment. Finally, these features in combination with a user-friendly interface (1-click to measure) significantly speed-up testing procedure and make it safer.These instruments store up to 1000 measurements on the internal micro SD card.Our free DV Win software communicates with the RMO-H micro-ohmmeters via a wireless Bluetooth interface. Furthermore, it allows you to download test results, analysis and generate fully configurable test reports.
-
product
Battery Voltage Supervisor
BVS
DV Power battery voltage supervisor – BVS, is an accurate battery voltage monitoring system that monitors the state of health of battery systems. It records important battery parameters such as battery voltage, inter-cell connection voltage, and ambient temperature. Because of that, it can be a support tool for capacity testing.The BVS voltage supervisor is an integrated system consisting of:BVS Control Unit (BVS-CU)Cell Voltage Modules (CVM)String Voltage Module (SVM) (optional)String Current Module (SCM) (optional)It is an ideal testing tool for maintenance, troubleshooting and performance tests on individual stationary batteries and battery packs in critical backup energy solutions.BVS-CU provides ambient temperature measurements on multiple locations (4 temperature channels). Overall string voltage and string current monitoring can be achieved by using an optional string voltage module (SVM) and string current module (SCM).There are two types of DV Power battery voltage supervisors:BVS – One cell voltage module measures 1 cellBVS-4 – One cell voltage module measures 4 cellsCVM modules detect cells that fail a discharge test based on monitored voltage values. As a result of that, these cells can be safely removed from the battery string.Data acquisition and analysis of data collected from the modules are available in the DV-B Win application software suite. They provide data viewing, tracking, and generation of comprehensive reports.
-
product
Battery Voltage Recorder
BVR Series
Battery voltage recorders from BVR series are designed to serve as a support tool for cell voltage measurement during battery capacity testing.During capacity testing, cell voltage, temperature, inter-cell connection voltage, and specific gravity should be measured in order to determine failling cells in the string that should be replaced.Furthermore, IEEE standards for stationary batteries applications stipulate periodical measurement of overall string voltage, as well as cell voltage and temperature.The BVR Series is the perfect tool for that purpose. All measurements are automatically saved in device’s internal memory. Additionally, DV-B Win software helps the user to download all measured results. Furthermore, the user can create test reports and export them to various formats.BVR series includes two models: BVR11 and BVR22. These are rechargeable handheld devices intended for performing monthly battery inspections and support tools during capacity testing. The list of the applications of these instruments includes:Efficient supplement to BLU series of battery load units during battery discharge testingMonthly inspections of large battery banksAmbient temperature measurementCurrent measurement using current clampsUSB and Bluetooth communication with PCSimultaneous string voltage and current measurement to analyze a discharge test processThe BVR22 model provides Bluetooth communication with an external density meter, for transferring electrolyte specific gravity and temperature readings.
-
product
Battery Capacity Testers|Discharge Testers
DV Power offers a wide range of battery capacity testers to meet specific customer needs. All of them are portable, powerful and most of all universal. Any battery string, such as lead-acid, lithium-ion, nickel-cadmium based and others, with voltages in the range of 0,9 – 800 V DC can be tested in an accurate, user-friendly way.The capacity test is carried out following the battery testing standards: IEEE 450-2010, IEEE 1188-2005, IEEE 1106-2015, IEC 60896-11/22, and other relevant standards.BLU battery testers enable setting the discharge current up to 350 A, with 0,1 A resolution. If higher currents are required, several units can be connected in parallel, or BXL additional load units can be used. Discharge parameters can be monitored in real-time during the capacity test. Overall battery voltage, current, elapsed test time and capacity will be presented during the entire test on a touch screen display.
-
product
Three-Phase Transformer Winding Resistance Meters
TWA Standard Series
When it comes to winding resistance measurement on three-phase power transformers and autotransformers, TWA Standard series offers some of the most technically advanced instruments with LCD display in the market. Both models are capable of testing six transformer windings with a one-time cable connection, as well as three-phase automatic transformer demagnetization. The stored magnetic energy is safely automatically discharged at the end of the test. The built-in tap changer control unit enables automated test mode, where the instrument operates the tap changer without operator input and records winding resistance results based on pre-selected stabilization criteria. This option makes the operator’s job significantly easier.Both models can output test currents from 5 mA to 25 A DC for the purpose of winding resistance measurement. TWA40D has a special test mode for checking the synchronization of on-load tap changers with three phases simultaneously tested in parallel, in which the total test current can rise to up to 40 A DC.TWA40D has additional advantages when it comes to non-intrusive tap changer analysis. The unique DVtest method enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, simultaneously with the measurement of tap changer motor current which helps with the detection of motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or on three phases simultaneously. It can also be performed as an additional test simultaneously with the winding resistance test in all tap positions.An additional unique advantage of TWA40D is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer (connected in a YN configuration). This can significantly shorten the total testing time – for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.The test leads for TWA three-phase transformer winding ohmmeters are interchangeable with the TRT turns ratio testers, which means that both sets of tests can be performed with a single test lead connection to the power transformer terminals.
-
product
Software
DV-Win
An unique software application called DV-Win has been developed by DV Power as a tool compatible with all series of our instruments. Software automatically recognizes the device which is connected to a PC and activates appropriate form.
-
product
Coil Testers & Power Supplies
POB Series
Coil testers and power supply units, models POB30 and POB40 are ideal for commissioning and maintenance testing of circuit breakers. The station supply is not available. The POB series are power supply units implementing the latest power electronics technology. They are developed for use in switchyards, power and industrial environment. In addition to providing current and voltage for breaker testing, they can measure certain coil parameters.
-
product
Transformer Turns Ratio Testers
Transformer turns ratio testers from TRT series are DV Power instruments mainly designed for the measurement of power transformer turns ratio. Also, they measure transformer excitation current and phase shift. Special tests, such as automatic vector group detection and magnetic balance, can be performed on three-phase transformers and three-phase autotransformers.All models, except TRT03 series, have a built-in true three-phase power source, which is necessary for testing turns ratio of transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.DV Power turns ratio testers can output various test voltages for different applications. From the extremely low test voltage of 1 V AC that enables turns ratio verification of the majority of current transformers, up to the highest test voltage of 500 V AC that provides the most accurate turns ratio testing of power transformers used in power generation and transmission. By using the external booster, test voltage increases up to 5 kV AC in order to successfully test capacitive voltage transformers.All DV Power turns ratio testers have a built-in tap changer control unit. Because of that, it is possible to control the on-load tap changer (OLTC) directly from the device. In order to make the most out of this feature, the instrument and included DV-Win software can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions, and saving results. This option significantly facilitates and shortens the turns ratio testing time.TRT turns ratio testers use the same set of cables as three-phase winding ohmmeter & tap changer analyzers from the TWA series. Consequently, it enables one-time cable setup for performing eight tests:turns ratioexcitation currentphase anglemagnetic balancevector group detectionwinding resistanceon-load tap changer DVtestand demagnetization.
-
product
Three-Phase Transformer Demagnetizer
DEM60C
After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores. The best way to eliminate this source of potential problems is to use demagnetizer on the power or instrument transformer.The DEM60C is a fully automatic test instrument which performs three-phase transformer demagnetization. Transformer magnetic core demagnetization requires the application of AC current with magnitude decreasing to zero. DEM60C provides this AC current by internally changing the polarity of a controlled DC current. During the demagnetization process, the instrument supplies the current at decreasing magnitude for each step, following a proprietary algorithm. It can demagnetize single-phase and three-phase power transformers.The instrument can be connected to all three phases of a power transformer to be demagnetized, on either the primary or the secondary side. If a user selects specific vector diagrams for different types of transformers, DEM60C will run a specific demagnetization procedure for each transformer type (i.e., single phase, delta, wye/star, zig-zag.) without switching the test leads.DEM60C enables safe and efficient power transformer demagnetization. The instrument automatically regulates the injection of current and discharging energy from the inductance. During and after the operation, an intrinsically safe discharge circuit with an indicator rapidly dissipates the stored magnetic energy. The discharging circuit is independent of the power supply, which improves its reliability in case of loss of power.Test currents of up to 60 A DC enable efficient demagnetization of even the largest power transformers. Using a DV Win software, it is possible to control DEM60C externally.
-
product
Coil Analyzers & Power Supplies
Coil analyzers and power supply units are portable and lightweight devices intended for use in harsh switchyard and industrial environments. The typical application is switchgear and circuit breaker testing when substation battery is not connected or available. An advantage over substation battery is enabled testing in under-voltage and over-voltage conditions. Furthermore, the stable voltage outputs with a very low ripple (<0,5%) enable an analysis of the coil and motor current graphs recorded with circuit breaker analyzers from different vendors.SAT40AD, POB30AD, and POB40AD are unique devices in the market due to their dual purpose:Power supply for coils and spring-charging motorsTesting circuit breaker’s coils, motor, and auxiliary circuitAll DV Power coil analyzers and power supply units have four separate outputs for opening and closing coils.SAT40AD has two powerful motor outputs (AC and DC) which can withstand up to 40 A inrush current.POB30AD and POB40AD have DC motor output rated up to 30 A and 40 A respectively. With the use of motor outputs, POB and SAT can also be used as a power source or a temporary battery charger.SAT40A II series instruments can be controlled via PC. The DV-Win application software is used to control both SAT and CAT (Circuit Breaker Analyzers & Timers) devices at the same time, making a unique test system for switchgear and circuit breaker testing.
-
product
Turns Ratio Testers
TRT Advanced Series
TRT Advanced series is the newest DV Power solution for transformer turns ratio measurement. Besides its main application, each turns ratio tester from this series also measures transformer excitation current and phase shift. Furthermore, all models perform automatic vector group detection and magnetic balance on three-phase transformers and three-phase autotransformers. They have a built-in true three-phase power source. For that reason, they can test transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.The instruments can output test voltages from 1 V AC to 500 V AC, depending on the model. With the highest test voltage 500 V AC, TRT500 provides the most accurate turns ratio testing of power transformers used in power generation and transmission. The output test voltage of TRT500 can be boosted to 5 kV AC using the external CVT20 extension transformer. This application is specially designed for testing turns ratio of capacitive voltage transformers. The other three models, TRT400, TRT250, and TRT100 can output up to 400 V, 250 V, and 170 V respectively. The low test voltage of 1 V AC enables turns ratio verification of current transformers.TRT500 is equipped with a large 10.1” graphical touch screen display. Other models, (TRT400, TRT250, TRT100) have 7” graphical touch screen display. Besides making the interface much more user-friendly compared to older turns ratio testers, it also brings certain options that were previously available only with DV-Win software. The most important are test templates and automatic test mode. Users can simply create test templates, store them in the instrument’s memory, and load when in the field with just a few clicks.This turns ratio test set, as well as all other DV Power turns ratio testers, has a built-in tap changer control unit. It enables remote control of an on-load tap changer (OLTC) directly from the instrument. In order to make the most out of this feature, the instrument can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions, and saving results. This option, especially in combination with test templates, significantly facilitates and shortens the turns ratio testing time. Automatic test mode minimizes human errors, which makes the measurement more reliable.
-
product
Single-Phase Transformer Winding Resistance Meters
RMO-TW Series
RMO-TW series is perfect for winding resistance measurements of inductive objects. It is ideal for testing transformer windings (power transformers, distribution, autotransformers) and for on-load tap changer verification. In addition, any RMO-TW transformer ohmmeter & tap changer analyzer can also perform transformer demagnetization.The series contains 4 models, with maximal test currents from 10 A (RMO10TW) to 50 A (RMO50TW). They are fitted in a portable and lightweight metal housing.All transformer ohmmeters from RMO-TW series generate a true DC ripple-free current with automatically regulated measurement and discharging circuit. The injection of current and discharge of energy from the test object are automatically regulated.Three independent channels enable testing of three windings in series. Consequently, this enables measurements of winding resistance in every tap position of an on-load tap changer without discharging between the tests.DV-Win software enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test. Finally, a user can export all results in the form of a report.
-
product
Battery Chargers
Following a power outage, various power engineering objects such as power plants should operate on battery back-up systems. It is necessary that these batteries are being properly charged in order to compensate its energy loss and keep their voltage within the predefined limits. DV Power’s chargers are portable and universal battery charging solution. They are primarily intended for charging Lead-Acid, Ni-Cd and Li-ion batteries from 1 V DC to 300 V DC level.Charging modes provide a safe regulation of charging procedure and achieves fast recharge and low risk of overcharge. Variety of implemented protections, such as thermal, overcurrent, undervoltage and overvoltage, assure the charging process is safe for the battery and the charger itself.